Fusion AI Solar Logo
FUSION AI SOLAR

Industrial Clean Energy EPC • BESS

Home / Solar Solutions / Multan & Khanewal / Cold Storage
2000 kWp Turnkey Solar EPC 2500 kWh Liquid-Cooled BESS Multan & Khanewal • MEPCO Grid Payback: 1.85 Years

2000 kWp Solar EPC & 2500 kWh BESS for Cold Storage in Multan & Khanewal (MEPCO)

Complete turnkey engineering feasibility for Cold Storage & Refrigerated Warehouses operating across Multan Industrial Estate Phase I & II, Vehari Road, Khanewal Processing Belt. Designed to eliminate daytime grid consumption, eradicate MEPCO peak-hour penalty charges (5:00 PM – 10:00 PM), and stabilize critical power quality.

Annual Clean Generation 3060,000 kWh Specific Yield 1,530 kWh/kWp
Projected Annual Savings PKR 208.5M Direct Recurrent Cashflow
Turnkey EPC CAPEX PKR 386.0M Panels, BESS & Net-Metering
Simple Capital Payback 1.85 Years IRR > 35% Equity Return
2000 kWp Solar EPC & 2500 kWh BESS for Cold Storage in Multan & Khanewal (MEPCO)
Industrial Archetype Reference

Cold Storage & Refrigerated Warehouses • Multan & Khanewal

Engineered with 3120x 640W N-Type TOPCon bifacial modules (4.0x 40HC containers) across 160,000 sq ft of roof area.

Operational Context

Power Dynamics for Cold Storage in Multan & Khanewal

Current Grid Infrastructure & Tariff Impact:

Diesel generators cost PKR 125+/kWh during daytime load shedding; temperature spikes ruin perishable inventories.

Operating under MEPCO industrial tariff regulations, the current blended rate exceeds PKR 64.0/kWh after accounting for base tariffs, Fuel Price Adjustments (FPA), Financing Cost Surcharges (FC-SUR), and regional electricity duties.

Grid Feeder Voltage: 11kV Semi-Arid Industrial Rural Mixed Feeders
Regional Solar Irradiance: 4.4 Peak Sun Hours / Day
Grid Quality Factor: Extreme summer ambient temperatures (+48°C) causing high distribution transformer losses

The Fusion AI Solar Engineered Solution:

By deploying a customized 2000 kWp Solar Array coupled with 2500 kWh of Liquid-Cooled LiFePO4 BESS Storage, the facility achieves complete daytime self-reliance.

  • Compressor peak surge support and 5:00 PM – 10:00 PM peak tariff eradication
  • Thermal-bridge-free standing seam clamps preserving cold-insulation thermal resistance
  • Automated LESCO / MEPCO reverse power zero-export control
  • Cloud dispatch telemetry via Hermes AI OS
Engineering Specifications

Turnkey Equipment Bill of Quantities (BOQ)

Subsystem Specification & Manufacturer Standard Quantity / Rating Warranty
PV Modules Tier-1 N-Type TOPCon Dual-Glass Bifacial (585W–725W, 22.5%+ Efficiency) 3120 Units (4.0x 40HC Container) 12-Yr Product / 30-Yr Linear
Inverters 16x 125 kW String Inverters + 2.5 MVA 0.8kV/11kV Oil-Immersed Step-Up Transformer with Smart String I-V Curve Diagnosis High-Voltage 1100V Decentralized 5-Yr Standard / 10-Yr Extended
BESS Storage 1x 2.5 MWh 40ft Containerized LiFePO4 Energy Storage Block with Central PCS (6,000 Cycles @ 90% DoD, Liquid Chiller Differential ≤ 2.5°C) 2500 kWh Capacity 10-Yr Operational Warranty
Mounting Structure Thermal-bridge-free standing seam clamps preserving cold-insulation thermal resistance (Wind Rating 150 km/h) 160,000 sq ft Area 25-Yr Anti-Corrosion
BOS & Protection Copper DC cables (XLPO 1.5kV), motorized DC disconnects, Type II SPD, 11kV HT metering unit Complete Turnkey Package 1-Yr EPC O&M Comprehensive
Frequently Asked Questions

Engineering & DISCO Compliance FAQs

Q. What is the estimated payback period for a 2000 kWp solar plant at Cold Storage in Multan & Khanewal?

Based on 2026 MEPCO tariffs (~PKR 64.0/kWh blended and PKR 78.20/kWh peak rate), the simple capital payback period is estimated at 1.85 years. Annual operational electricity savings reach approximately PKR 208.5 Million.

Q. How does the 2500 kWh LiFePO4 BESS eliminate MEPCO peak charges?

The containerized liquid-cooled battery system charges during midday solar peak hours at a levelized cost of ~PKR 9.50/kWh, and automatically discharges during the mandatory MEPCO 5:00 PM – 10:00 PM peak window, completely neutralizing grid peak penalty tariffs.

Q. How is roof leakage prevented on Cold Storage & Refrigerated Warehouses PIR Insulated Cold Room Roofing?

We utilize Thermal-bridge-free standing seam clamps preserving cold-insulation thermal resistance, which preserves structural manufacturer warranties and eliminates water seepage risks while resisting 150 km/h wind uplift.

Q. Does Fusion AI Solar handle MEPCO net-metering approvals in Multan & Khanewal?

Yes. Fusion AI Solar provides complete turnkey engineering and regulatory management, including Distribution Transformer load clearance, NEPRA generation license application, reverse power relay commissioning, and green two-way bi-directional meter activation.

Ready for Site Survey?

Deploy 2000 kWp Solar for Cold Storage in Multan & Khanewal

Connect directly with our Chief Solar Architect and CEO on WhatsApp. We provide full bill analysis and structural survey within 48 hours.

Request Official Proposal on WhatsApp